Other |
KIT-WXC16H9E8 |
Heating capacity (A +7°C, W 35°C) |
kW |
16.00 |
COP (A +7°C, W 35°C) |
4.28 |
Heating capacity (A +7°C, W 55°C) |
kW |
16.00 |
COP (A +7°C, W 55°C) |
2.71 |
Heating capacity (A +2°C, W 35°C) |
kW |
16.00 |
COP (A +2°C, W 35°C) |
3.10 |
Heating capacity (A +2°C, W 55°C) |
kW |
16.00 |
COP (A +2°C, W 55°C) |
2.13 |
Heating capacity (A -7°C, W 35°C) |
kW |
16.00 |
COP (A -7°C, W 35°C) |
2.49 |
Heating capacity (A -7°C, W 55°C) |
kW |
16.00 |
COP (A -7°C, W 55°C) |
1.86 |
Cooling capacity (A 35°C, W 7°C) |
kW |
12,20 |
EER (A 35°C, W 7°C) |
2.57 |
Cooling capacity (A 35°C, W 18°C) |
kW |
12,20 |
EER (A 35°C, W 18°C) |
3.49 |
Heating average climate. Seasonal energy efficiency (W 35°C / W 55°C) |
ηs % |
160 / 125 |
Heating average climate. Seasonal energy efficiency (W 35°C / W 55°C) |
SCOP |
4.08 / 3.20 |
Heating average climate. Energy class (W 35°C / W 55°C) (1) |
A+++ to D |
A++ / A++ |
Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C) |
ηs % |
231 / 159 |
Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C) |
SCOP |
5.85 / 4.05 |
Heating warm climate. Energy class (W 35°C / W 55°C) (1) |
A+++ to D |
A+++ / A+++ |
Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C) |
ηs % |
150 / 125 |
Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C) |
SCOP |
3.83 / 3.20 |
Heating cold climate. Energy class (W 35°C / W 55°C) (1) |
A+++ to D |
A++ / A++ |
Indoor unit |
WH-SXC16H9E8 |
Indoor sound pressure (Heat) |
dB(A) |
33 |
Indoor sound pressure (Cool) |
dB(A) |
33 |
Indoor dimension (Height) |
mm |
892 |
Indoor dimension (Width) |
mm |
500 |
Indoor dimension (Depth) |
mm |
340 |
Indoor net weight |
kg |
45 |
Water pipe connector |
Inch |
R 1¼ |
A class pump (Number of speeds) |
Variable Speed |
A class pump (Input power Min) |
W |
30 |
A class pump (Input power Max) |
W |
105 |
Heating water flow (∆T=5 K. 35°C) |
l/min |
45.90 |
Capacity of integrated electric heater |
kW |
9.00 |
Indoor recommended fuse |
A |
16 / 16 |
Recommended cable size, supply 1 |
mm² |
5 x 1.5 |
Recommended cable size, supply 2 |
mm² |
5 x 1.5 |
Outdoor unit |
WH-UX16HE8 |
Outdoor sound power part load (Heat) (3) |
dB(A) |
67 |
Outdoor sound power full load (Heat) |
dB(A) |
72 |
Outdoor sound power full load (Cool) |
dB(A) |
71 |
Outdoor dimension (Height) |
mm |
1340 |
Outdoor dimension (Width) |
mm |
900 |
Outdoor dimension (Depth) |
mm |
320 |
Outdoor net weight |
kg |
118 |
Refrigerant (R410A) / CO2 Eq. |
kg / T |
2.90 / 6.055 |
Pipe diameter (Liquid) |
Inches (mm) |
3/8 (9.52) |
Pipe diameter (Gas) |
Inches (mm) |
5/8 (15.88) |
Pipe length range |
m |
3 ~ 30 |
Elevation difference (in/out) |
m |
30 |
Pipe length for additional gas |
m |
10 |
Additional gas amount |
g/m |
50 |
Operating range (Outdoor ambient) |
°C |
-28 ~ +35 |
Water outlet (Heat) |
°C |
20~60 |
Water outlet (Cool) |
°C |
5 ~ 20 |